Image Supply Output
signal
Sealing
grade
Temp. range
Angle range (degrees)
Output voltage range Connector Return spring Absolute linearity Resistance Life time full stroke Download
PDF

 5 V/5 mA max per signal  1 or 2 signals  IP 67/IP 69 -40 °C to +120 °C (+130 °C /1h)  70° up to 120°  0.5 V - 4.5 V Tyco/MQS 6 Pins No ± 1%  >10 mio 91_732.pdf

 5 ± 0.1 V analogic, voltage interface  IP 54  -40 °C to +125 °C 86° 0.68 V - 4.25 V No ± 2.5% 4.1 kOhm
± 20%
 min. 2 mio cycles

41_665.pdf


 5 ± 0,1 V analogic, voltage interface  IP 54

 -40 °C to +120 °C

 105°  0.15 V - 5 V  – Yes  ± 3% 4,0 kOhm
± 20%
 min. 2 mio cycles

41_624.pdf


5 V/5 mA max per signal analogic, voltage interface, 1 or 2 signals IP 67/ IP 69 -40 °C to +120 °C (+130 °C /1h) 30° up to 360° 0.5 V - 4.5 V  Tyco/MQS 6 Pins No   ± 1%  – >10 mio

92_201.pdf


5 V/5 mA max per signal analogic, voltage interface, 1 or 2 signals IP 67/ IP 69 40 °C to +120 °C (+130 °C /1h) 30° up to 360° 0.5 V - 4.5 V Tyco/MQS 6 Pins No ± 1% >10 mio 91_812.pdf

5 V/5 mA max per signal analogic, voltage interface, 1 or 2 signals IP 67/ IP 69 -40 °C to +120 °C (+130 °C /1h) 30° up to 360° 0.5 V - 4.5 V Tyco/MQS 6 Pins No ± 1% >10 mio 91_681.pdf

5 V/5 mA max per signal analogic, voltage interface, 1 or 2 signals IP 67/ IP 69 -40 °C to +120 °C (+130 °C /1h) 30° up to 360° 0.5 V - 4.5 V Tyco/MQS 6 Pins No ± 1% >10 mio 91_680.pdf

5 V/5 mA max per signal 1 or 2 signals IP 67/ IP 69 -40 °C to +120 °C (+130 °C /1h) 70° up to 120° 0.5 V - 4.5 V Tyco/MQS 6 Pins No ± 1% >10 mio 91_400.pdf

5 V/5 mA max per signal analogic, voltage interface, 1 or 2 signals IP 67/ IP 69 -40 °C to +120 °C (+130 °C /1h) 30° up to 360 0.5 V - 4.5 V Tyco/MQS 6 Pins No ± 1% >10 mio 91_776.pdf

5 V/5 mA max per signal analogic, voltage interface, 1 or 2 signals IP 67/ IP 69
-40 °C to +120 °C (+130 °C /1h)
 
30° up to 360 0.5 V - 4.5 V Tyco/MQS 6 Pins No ± 1% >10 mio 91_813.pdf

5 V/5 mA max per signal 1 or 2 signals IP 67/ IP 69 -40 °C to +120 °C (+130 °C /1h) 70° up to 120° 0.5 V - 4.5 V Tyco/MQS 6 Pins No ± 1% >10 mio 91_743 .pdf

 5 V/5 mA max per signal  analogic, voltage interface, 1 or 2 signals  IP 67/ IP 69  -40 °C to +120 °C (+130 °C /1h) 30° up to 360 0.5 V - 4.5 V Tyco/MQS 6 Pins  No ± 1%  – >10 mio 92_200.pdf

 5 V/5 mA max per signal 1 or 2 signals IP 67/ IP 69   -40 °C to +120 °C (+130 °C /1h)  70° up to 120°  0.5 V - 4.5 V Tyco/MQS 6 Pins  No ± 1% >10 mio  91_819 .pdf